Feasibilityofusing100kVptechniqueinrenalarteryCTangiographywithiodixanol(270mgI/mL)

雷平贵,赵永为,王霄英,王鹤,张保翠,杨学东,高福生
DOI: https://doi.org/10.13609/j.cnki.1000-0313.2014.04.005
2014-01-01
Abstract:Objective:To evaluate the feasibility of using 100kVp technique with iodixanol (270mg I/mL)in renal computed tomography angiography (CTA).Methods:Sixteen consecutive patients underwent renal artery CTA.They were divided into 100kVp group (10 patients)and 120kVp group (6 patients).The radiation dose and size-specific dose estima-tion (SSDE)of these two groups were recorded.The image quality was evaluated subjectively with 5 scale method by two experienced radiologists,including image quality as a whole,detail image quality (sharpness of blood vessels,blood vessel branches displayed on MPR,VR and MIP).The objective evaluation included attenuation of aimed blood vessels (abdominal aorta,bilateral renal arteries)and the attenuation of psoas major muscle at the same level as reference,and contrast-to-noise ratio (CNR),signal-to-noise ratio (SNR)were calculated.The radiation dose and objective evaluation parameters were stati-cally analyzed withttest,and the subjective evaluation parameters were analyzed with Mann-Whitney U test.Results:The CTDIvol in 100kVp group was (11.19±3.85)mGy,in 120kVp group was (17.37±2.63)mGy,with significant statistic difference (P<0.05).The SSDE of 100kVp group was (15.48±4.41)mGy,in 120kVp group was (25.00±2.49)mGy, with significant statistic difference (P<0.05).There was no significant difference in the image quality as a whole in subjec-tive evaluation between the 2 groups (Z= -1.60,P>0.05).Significant difference was existed in the sharpness of blood vessels between the 2 groups (Z= -2.162,P<0.05);whereas no statistic difference was showed in the vessel branches displayed on MPR,VR and MIP (Z= -0.972,P>0.05;Z= -1.696,P>0.05;Z= -1.626,P>0.05),respectively.For objective evaluation,the CT values of abdominal aorta and renal artery in 100kVp group and 120kVp group was [(291±32) vs (224±20)HU,P<0.05)]and [(278±37)vs (222±15)HU,P<0.05)]respectively,with significant statistic diffe-rences.The CT value and standard deviation in 100kVp group was (-992 ±2)and (9 ±2)HU respectively,in 120kVp group was (-995±2)and (7±2)HU respectively,with no statistic difference (P>0.05).The CNR and SNR in 100kVp group and 120kVp group were (22±4)vs (21±3),and (30±7)vs (30±6)respectively,with no statistic difference (P>0.05).Conclusion:Renal CTA with 100kVp and iodixanol (270mg I/mL)as contrast medium can provide satisfactory im-age quality as well as significant reduction of radiation exposure.
What problem does this paper attempt to address?