Detection of Coronary Artery Stenosis Using 16-Slice Spiral CT:Comparison with Catheterization Coronary Angiography

王照谦,杨志强,朱皓,周旭臣,郑晓群,曲新凯,刘晓峰,方唯一
DOI: https://doi.org/10.3969/j.issn.1000-0313.2005.03.002
2005-01-01
Abstract:Objective:To evaluate the accuracy of 16-slice spiral CT in detecting coronary artery stenosis.Methods:A total of 55 consecutive patients with known or suspected coronary artery disease were studied by 16-slice spiral CT (retrospectively ECG-gating;0.5s rotation;one-sector or two-sector reconstruction algorithm;intravenous contrast agent).The results were compared with catheterization coronary angiography.Results:In the 568 coronary artery segments of 55 patients,492 were judged to be evaluable by CT (86.6%),56 of 64 coronary artery segments with significant stenosis (≥50% reduction of vessel diameter) were correctly detected by CT,416 of 428 coronary artery segments with normal or mild stenoses (50% reduction of vessel diameter) were correctly detected by CT.These values corresponded to a sensitivity of 87.5%,specificity of 97.2%,positive predictive value of 82.4%,and negative predictive value of 98.1% for the detection of significant coronary artery segments stenoses by CT.In the 492 evaluable coronary artery segments,33 of 36 coronary artery segments with high-grade stenosis (≥75% reduction of vessel diameter) were correctly detected by CT,450 of 456 coronary artery segments with normal or stenoses (75% reduction of vessel diameter) were correctly detected by CT.These values correspond to a sensitivity of 91.6%,specificity of 98.7%,positive predictive value of 84.6%,and negative predictive value of 99.3% for the detection of high-grade coronary artery segments stenoses by CT.Conclusion:16-slice spiral CT with retrospectively ECG-gating permits the visualization of significant coronary artery stenoses with high accuracy if image quality is sufficient.
What problem does this paper attempt to address?