Determination of Atropine in Plasma and Urine by HPLC

JIN Ming,ZHANG Fu-rong,CAI Xiang-yang,ZHOU Yi-wu
DOI: https://doi.org/10.3321/j.issn:1001-5213.2005.05.018
2005-01-01
Abstract:OBJECTIVE For the purpose of more accurate and rapid analysis of atropine in plasma and urine,a reversed-phase high performance liquid chromatography (HPLC) method was developed.METHODS Standard atropine was added to the blank plasma and urine when the samples were pretreated. The pretreatment method of samples,the linear range,the precision,the recoveries in the plasma were investigated by using of human plasma and urine spiked with standard atropine.RESULTS The linear range were ~0.2 -~ 5.0 mg ·L~-1 ,r=0.~999 2 in plasma and r=~0.998 8 in urine. The detective limits were ~0.2 mg ·L~-1 . The intra and inter-day precision of assay for atropine were less than ~3.2% and ~4.0% (n=5) in plasma,~3.6% and ~4.7% in urine respectively.The recoveries of atropine were more (~97.0 ±~2.1 )% in plasma and (~97.8 ±~2.9 )% in urine. The HPLC method had been used to investigate the concentration of atropine in many forensic medicine cases.CONCLUSION The HPLC method of quantitative analysis atropine is simple,rapid and accurate. It is suitable for the concentration monitoring of atropine in the clinical first aid and forensic medicine.
What problem does this paper attempt to address?