Determination of Antipyrine in Plasma by Reversed Phase High-Performance Liquid Chromatography

Shanxiang Jiang
2006-01-01
Abstract:AI M:To establisha reversed phase high-performance liquid chromatography method for the deter-mination of antipyrine in plasma.METHODS: Plasmasamples were prepared with acetonitrile.The chromato-graphic separation was performed on a Kromasil C18col-umn at columntemperature of 30 ℃.The mobile phase,a mixture of 0.025 mol.L-1aqueous solution of sodiumacetate and acetonitrile(74 26,v/v),was delivered ata flowrate of 0.8 ml.min-1.The detection wavelengthwas 254 nmandthe sample size was 20μl.RESULTS:Excellent line relationship was obtained in the range of0.1 to 30μg.ml-1(r=0.9995).The average recoveryrate was 93.44 %-97.21 %.The intra-day and inter-day coefficients of differentiation were both less than4.26 %.CONCLUTION:The methodis simple,accu-rate and can be usedfor studies onthe model of antipyrinepharmacokinetics.
What problem does this paper attempt to address?