Mechanism analysis of wind-induced response for hyperbolic cooling towers

TIAN Yongsheng,DING Dayi,ZOU Yunfeng,HE Xuhui,CHEN Zhengqing,NIU Huawei
DOI: https://doi.org/10.19713/j.cnki.43-1423/u.2018.07.023
2018-01-01
Abstract:Wind loading is the control load in the design of cooling towers, and wind-induced interference attracts more attention of people. Based on the Fourier-series expression of pressure curves given in the relevant specifications, the contributions of each harmonic to both drag coefficient and wind-induced response were analyzed. Taking a 200 m high cooling tower for example, the mechanism of wind-induced response of cooling towers was analyzed and verified using finite element method. The present results reveal further insight into the mechanism of wind-induced response of cooling towers, and provide a reference for selecting appropriate method to investigate wind-induced interference of cooling towers.