Analysis on operation cost of SCR system in coal-fired power plant

Hang YANG,Cheng-hang ZHENG,Kan JIN,Jun ZHANG,Yong-xin ZHANG,Wei-guo WENG,Xue-cheng WU,Xiang GAO
DOI: https://doi.org/10.3785/j.issn.1008-973X.2017.02.019
2017-01-01
Abstract:An operation cost assessment system and calculation model of selective catalytic reduction (SCR) system in coal-fired power plant was established based on cost-benefit analysis.The operation cost of SCR system in typical unit was investigated.Results show that the operation cost of SCR system in large capacity unit is lower than that in small capacity unit.When the annual operation hours are 5 000 h and NOx inlet concentration is 400 mg/m3 (the oxygen content of base condition is 6%),the operation cost of SCR system in typical 300, 600 and 1 000 MW power unit are among 7.60~8.60, 5.75~6.55 and 4.80~5.40 yuan/MW·h, respectively.When the NOx inlet concentration increases from 200 mg/m3 to 400 mg/m3 and to 600 mg/m3, the reductant cost in the total operation cost has the largest increase, by 195.90% and 391.00%, respectively.When the emission is up to ultra-low emission standard, compared to the GB13223-2011 standard, the operation cost of 300, 600 and 1 000 MW increases by 9.64%, 9.68% and9.80%.When the annual service hours increase from 4 000 h to 6 000 h, the operation cost of 300, 600 and 1 000 MW decreases by 28.00%, 26.00% and 26.20%.