Abstract:This paper takes it as its goal to analyze the exhaled bioaerosol particles in a well-ventilated room condition for a physical exerciser. For the given research purpose,we are trying to discuss and represent different kinds of force spent on it physical exercises,such as the drag force,the gravitational force,Brownian force,the thermophoretic force,and Saffman s lifting force,which are convenient as well as scientifically rational for us to calculate the exhaled bioaerosol particles in a well-ventilated room.The decisive factors,such as exhaled particle size,the inside-room air velocity,room air temperature, velocity gradient,and temperature gradient,which are all needed to determine so that the above-said forces can be adopted in accordance with the recent experimental data on the exhaled droplet sizes and ASHRAE handbooks.In addition,the so-called drag force, Brownian force,thermophoretic force,Saffman' s lift force,are also likely to be derived as a function of particle diameter.Thus,from our work,it can be found that the particle diameter should be made the dominant factor affecting the relative magnitude of all the other forms of force under discussion.With the increase of particle diameter,the magnitudes of other forces,such as Brownian force,drag force,thermophoretic force,and Saffman's lift force all tend to decrease.We have also found that the influence of particle diameter on the Brownian force proves to be the most significant,which is followed by the drag force,thermophoretic force,and then the impact on Saffman's lift force.The relative magnitudes of these forces can likely be normalized by the gravitational force at different particle-size levels. And,subsequently,the drag force,Brownian force,and Saffman's lift force of the so-called sub-microsome particles,are all larger than the gravitational force,also forces that shouldn t be ignored when analyzing the movement of sub-micro particles indoors.Since the thermophoretic force seems always smaller than the gravitational force in the indoor environment,it would become noticeable in the locations that were very close to heat sources,where there was a steep temperature gradient.For coarse particles (larger than 5 μm),the drag force and gravitational force would be the main factors controlling particle movements.In this circumstance,it was reasonable to overlook the other forces when keeping an acceptable accuracy.From what is said above,we can give a proper reference for the selection and sometimes simplification of simulation models for particle movements indoors.