Wind-induced response of a 5 00 kV single-circuit transmission tower based on high-frequency force-balance technique

Qing-hua ZHANG,Ming GU
DOI: https://doi.org/10.3969/j.issn.1000-3835.2014.04.028
2014-01-01
Abstract:Wind-induced responses of a 500kV single-circuit transmission tower were computed based on wind forces acting on the tower obtained from wind tunnel tests using high-frequency force-balance technique and the modal superposition method.The results showed that the dynamic response displacements,accelerations and base bending moments (BBM)are all large in both along and across wind directions,and furthermore,the across wind dynamic responses are generally larger than the along wind responses;the first mode has dominant contributions to the total response in both the two wind directions;in addition,the displacement gust response factor and the BBM response factor have similar trends;the maximum displacement gust response factor in along wind direction of key nodes is no more than 1.8,and the maximum moment gust response factor is about 1.5.
What problem does this paper attempt to address?