Feasibility study of anti-strong-wind cable-tower structure

Zhang Zihua,Liu Guohua,Wang Zhenyu,Wu Zhigen
2009-01-01
Abstract:In order to improve the safety and economy of wind power structures located in typhoon-prone areas,a cable-tower structure(CTS) based on the combination of prestressed cables and a wind turbine tower was proposed.Dynamic balance equation of the CTS was derived based on nonlinear vibration theory.Prestressed catenary element,solid element and shell element were employed to build finite element models of a tower structure and CTS with both heights of 65 m,and natural vibration characteristics of the two types of structures and their dynamic responses under 50-year extreme operational gust were calculated.The results show that the first and second order natural frequencies of the CTS are about 11.3% larger than those of the tower structure,while the third to tenth order natural frequencies of these two structures are similar.Obviously,compared with the tower structure,the excessive horizontal displacement of the hub,the maximum equivalent stress and high equivalent stress area of the windward point located on the bottom of the tower,and the variation range of the axial force in the windward pile are smaller in the CTS,except for the maximum of the axial force of a single pile.Generally,under the strong wind condition,the mechanical properties of the CTS are better than those of the existent tower structure.
What problem does this paper attempt to address?