Mean Wind Loads on T-shaped Angle Transmission Towers

Guohui Shen,Kanghui Han,Baoheng Li,Jianfeng Yao
DOI: https://doi.org/10.12989/was.2024.38.5.367
2024-01-01
Wind and Structures
Abstract:Compared with traditional transmission towers, T-shaped angle towers have long cross-arms and are specially used for ultrahigh-voltage direct-current (UHVDC) transmission. Nevertheless, the wind loads of T-shaped towers have not received much attention in previous studies. Consequently, a series of wind tunnel tests on the T-shaped towers featuring cross-arms of varying lengths were conducted using the high-frequency force balance (HFFB) technique. The test results reveal that the Tshaped tower's drag coefficients nearly remain constant at different testing velocities, demonstrating that Reynolds number effects are negligible in the test range of 1.26 x 10(4)-2.30 x 10(4). The maximum values of the longitudinal base shear and torsion of the T-shaped tower are reached at 15 degrees and 25 degrees of wind incidence, respectively. In the yaw angle, the crosswind coefficients of the tower body are quite small, whereas those of the cross-arms are significant, and as a result, the assumption in some load codes (such as ASCE 74-2020, IEC 60826-2017 and EN 50341-1:2012) that the resultant force direction is the same as the wind direction may be inappropriate for the cross-arm situation. The fitting formulas for the wind load-distribution factors of the tower body and cross-arms are developed, respectively, which would greatly facilitate the determination of the wind loads on T-shaped angle towers.
What problem does this paper attempt to address?