Fluid flow and heat transfer characteristics on uncoated and micro porous straight and divergent heat exchangers for high-powered electronic devices
Mudhafar A. H. Mudhafar,Xu Yu-Feng
DOI: https://doi.org/10.1007/s00231-022-03282-3
2022-08-26
Abstract:This paper focuses on the enhancement of flow boiling heat transfer and improvement of flow instability due to the porous surface modification and channel section expansion, which is a hot research issue. The two-phase cooling system offers a potential solution for dissipating a large amount of heat at a very small area. There are too many articles on enhancing flow boiling heat transfer on smooth (non-coating) straight and divergent heat exchangers, however, all of them ignored the effect of the surface characterizations such as micro porous coating which is very significant parameter when presented and discussed the flow boiling results. Therefore, the major novelty of the current work is to improve the heat transfer performance of the heat exchanger by applying micro porous coatings on the linear and divergent heat exchangers as well as it aims at further understanding the effect of micro porous coatings under low and high heat flux conditions. The micro porous coatings were fabricated by spraying method with average particle size of 25 μm and having optimum thickness of 150 μm using FC-72 as a working fluid. The test results show that the micro porous coatings increase the active cavities, decrease the required vapour superheat, enhance the liquid replenishment to the heating surface, delay the dry-out phenomena, and decrease the vapour release resistance, and therefore, better enhancement in the performance of the system and critical heat flux up to 20% and 61% respectively. It was also observed that applying micro porous coating led to decrease thermal resistance by 35%. Moreover, the results depict that for the straight channel micro-micro-heat exchanger, the geometry of the flow path is very simple, and therefore, the pressure drop is very small compared to the divergent heat exchanger. For the divergent micro-heat exchanger, the pressure drops are higher than that of the straight channel micro-heat exchanger at varies vapor qualities since the fluid is distributed in the different flow channels, and this leads to higher pressure drops loss compared with the straight flow channels. In addition, the test results show that the flow boiling HTC and CHF are affected by the geometric configurations, i.e. the ability of increasing the heat transfer area, the ability to release the bubbles to the outlet of the channels, reducing the back flow, and delaying the dryness phenomena (CHF). For linear flow-channel surface, a stratified flow state of vapour in the upper layer and the liquid in the lower layer under low and high heat fluxes conditions dominates. For the divergent flow-channel surface, the results show that under low heat flux condition, the bubbles generated are easy to move downstream of the flow channel, and there is no bubbles backflow phenomenon, but under high heat flux condition, the backflow phenomena occurs on the uncoated divergent-flow channel surface. However, attributing to the capillary action on the micro porous layer surface, the liquid can rewet the surface, and this enhances the flow boiling HTC as well as this delay the CHF.