A high accuracy current comparator with electronic compensation

He Li,Mohns Enrico,Min Lei,Wei Zhao,Shuhan Zhang,Haoliang Hu
DOI: https://doi.org/10.3969/j.issn.1001-1390.2017.19.016
2017-01-01
Abstract:Current transformer ( CT ) has been widely used in current ratio transformation .Normally, its accuracy hardly exceeds 0.01%.Some more accurate current ratio transformer devices , such as two-stage current transformer and compensated current comparator , can only be used in the traceability or distribution area of current ratio quantity of power frequency due to some limitations .In view of this situation , a current comparator with electronic compensa-tion ( ECCC) using electronic circuit to compensate the magnetizing current of the core was developed .The principle , theoretical analysis of the error , and the calibration tests are presented in the paper .The results showed that the EC-CC fulfills the requirements of the accuracy class of 0 .0005 .It can be used either as a high accuracy current ratio standard , or a normal CT in power frequency current measurement where high accuracy is needed .
What problem does this paper attempt to address?