Research on Automatic Compensation of Remnant-voltage of GMR Eddy Current Probe

Zhou Ze-kui
2008-01-01
Abstract:A new micro-controller based compensation method for remnant-voltage of the GMR eddy current probe was analyzed.Firstly,lock-in amplifier(LIA) technique was used to attain the amplitude of remnant-voltage and the phase difference between the remnant-voltage and the reference signal;Then,the micro-controller was applied to control NC phase-shifter and amplitude regulator to change the amplitude and phase of the reference signal,in order to obtain a compensation signal which was consistent with remnant-voltage;Finally,the output was close to zero after the subtraction between the compensation signal and remnant-voltage,and automatic compensation of remnant-voltage was achieved.Specimen aluminium was used in the detective experimental verification.After the automatic compensation of remnant-voltage by the technique,the output of the remnant-voltage of eddy current probe is about 4.05% of the one before compensation,the compensation accuracy fulfils the requirements of the detection system,which shows that the remnant-voltage compensation of eddy current probe can be realized by the technique and the technique improve the sensitivity of the eddy current system.Furthermore,it also can enhance the detection ability for deep-seated flaws of eddy current system.