Abstract:In this paper, the series resistance method was used to solve the problem that traditional impedance analyzer was difficult to meet the demands of resonance excitation.Piezoelectric micro cuboid resonator charge amplifiers equivalent circuit with special voltage incentives was researched.Through drawing piezoelectric resonator admittance circle diagram, the equivalent circuit parameters near the circuit parameters near the resonant frequency were obtained.Comparing the experimental results with and without charge amplifiers as the load connected to the piezoelectric resonator, it is found that resonance frequency with a charge amplifier of the piezoelectric resonator equivalent circuit reduced from 346.119 kHz to 344.979 kHz.The conclusion was drawn that if the charge amplifiers are used in the piezoelectric resonator, its effect on resonant frequency should be concerned.