Application of Digital Image Correlation Technique in Measuring Coefficient of Ther-mal Expansion at High Temperature

Zhong-ying XU,Wei WANG,Song-he MENG,Wei-hua XIE,Fa-jun YI
DOI: https://doi.org/10.7643/issn.1672-9242.2016.03.006
2016-01-01
Abstract:Objective To measure thermal expansion coefficient (CTE) of heat structures materials at high temperature.Me-thods Combining the digital image correlation (DIC) method and energized resistance heating technology, a test system for measuring high-temperature deformation and strain was established. After recording the surface images at different temperatures by a CCD camera, DIC method was used to analyze all the images to obtain the deformation and strain along with increasing temperature, and the corresponding thermal expansion coefficients at different temperatures were further calculated. This paper measured the thermal expansion coefficients of copper in the range of 600~800℃, and measured the graphite′s CTE in the range of 600 ~1200℃, comparing with literature data.Results The CTE of copper was in the range of 600 ~800℃ and gra-phite in the range of 600~1200℃ as, measured by this system, showing that the data were in good agreement with the litera-ture.Conclusion This method showed the ability to accurately measure thermal strain and CTE of conductive material, and its temperature limit reached up to 1200℃.
What problem does this paper attempt to address?