Theoretical Study on Wide Load Denitration of a 660 MW Supercritical Unit by Retrofitting the Feedwater Heating System

Guozhu ZHANG,Bingxin LI,Yawei LI,Fei LI,Benfeng LI,Jiping LIU
DOI: https://doi.org/10.3969/j.issn.1674-7607.2018.01.009
2018-01-01
Abstract:To improve the denitration efficiency and thermodynamic performance of a 660 MW supercritical unit operating at low load,a bypass line and high/low-pressure steam regulating valves were added to its original low-load feedwater heating system including a steam ejector,so as to achieve wide load denitration of the unit.The temperature rise of No.0 high-pressure heater was calculated,while the operation mode of the steam ejector operating at high load was optimized.Results show that for the unit load greater than 30 %,the No.0 high pressure heater has a large range of temperature rise to satisfy the denitration requirement.When the unit operates at high load,the thermal efficiency of the unit could be improved by reducing the pressure of high-pressure steam at inlet of the steam ejector.
What problem does this paper attempt to address?