Abstract:The coal-fired power plants operate frequently under off-design condition because of the load fluctuations in power grids caused by the rapid spread of power generation capacity from unpredictable renewable energy sources.Dynamic models of a 660 MW supercritical unit were established with the GSE software.The models have good accuracy with the error not more than ±0.5%.In this paper,the influence of the transient process of the unit load-up on denitrification and particle removal was studied.The results show that with the increase of unit load,the denitrification efficiency increases and the particle removal efficiency decreases gradually.During the load-up process,the transient stability time of denitrification is far less than the particle removal.At the same time,the denitrification efficiency of SCR shows a sudden decrease and then a rapid increase,and the efficiency of ESP firstly increases suddenly and then decreases to stable.When the amplitude of the load-up is large,SCR is prone to overshoot,resulting in NOx excessive emission.