Insulation State Detection Method for DC XLPE Cable

Jing ZHANG,Lin CHENG,Zhe LI,Zhengyang LIU,Zhengzheng CHEN
DOI: https://doi.org/10.11973/dlyny201905003
2019-01-01
Abstract:With the development of grid connection of new energy power generation,the application of DC cross-linked polyethylene (XLPE)cable is more and more extensive,but it remains a problem how to detect ef-fectively the running state of DC cable and how to evaluate its state.Based on the test platform for partial dis-charge and leakage current detection of DC XLPE cable,and the model of residual defects in sem-i conductive layer of XLPE cable,this research studied the characteristics of partial discharge and leakage current under dif-ferent voltage amplitudes and voltage polarities.The test results showed that the partial discharge and leakage current can be used to detected cable defects.While partial discharge under the function of negative and high voltage,the cable defect can be detected more easily,the characteristics of the leakage current under positive voltage changes significantly,and the obvious variation can be measured when the applied voltage is lower than the rated voltage,which is conducive to the state testing and evaluation of the running cable.Finally,the fea-sibility of using leakage current for live detection of DC cable state under operating conditions is proposed, which is of great value for improving the state detection of DC XLPE cable.
What problem does this paper attempt to address?