Application of Accelerated Evaluation Method of Alteration Temperature and Constant Dose Rate Irradiation on Bipolar Linear Regulator LM 317

DENG Wei,LU Wu,GUO Qi,HE Chengfa,WU Xue,WANG Xin,ZHANG Jinxin,ZHANG Xiaofu,ZHENG Qiwen,MA Wuying
DOI: https://doi.org/10.7538/yzk.2014.48.04.0727
2014-01-01
Abstract:With different irradiation methods including high dose rate irradiation ,low dose rate irradiation ,alteration temperature and constant dose rate irradiation ,and US military standard constant high temperature and constant dose rate irradiation , the ionizing radiation responses of bipolar linear regulator LM 317 from three different companies were investigated under the operating and zero biases .The results show that compared with constant high temperature and constant dose rate irradiation method ,the alteration temperature and constant dose rate irradiation method can not only very rapidly and accurately evaluate the dose rate effect of three bipolar linear regulators ,but also well simulate the damage of low dose rate irradiation .Experiment results make the alteration temperature and constant dose rate irradiation method successfully apply to bipolar linear regulator .
What problem does this paper attempt to address?