Abstract:To simulate floating potential defect, we designed a floating potential defect model. By setting up an experiment platform that can produce oscillating lightning impulse voltage that counld meet the re-quirements of IEC60060-3 and partial discharge measurement system, we studied the partial discharge characteristics of the common floating potential defect in SF6 gas under oscillating lightning impulse volt-age. The variation of discharge amplitude maximum and discharge number with the increase of voltage was studied. The results show that under the effect of oscillating lightning impulse voltage, the partial dis-charge of floating potential happen at the falling edge and rising edge of voltage. With the increase of voltage, the discharge amplitude maximum and discharge number increase, and the increase extent of the discharge number is greater than that of the discharge amplitude.