CT method for accurately sizing flaws in metallic material

Zicheng Qi,Peijun Ni,Wei Jiang,Weiguo Zhang,Zhimin Guo
DOI: https://doi.org/10.11884/HPLPB201830.170304
2018-01-01
High Power Laser and Particle Beams
Abstract:The model of CT measurement for X-ray attenuation in metallic materials was established by using image Point Spread function(PSF)approximation,the numerical calculation on the gray scale amplitude perpendicular to the X-ray plane boundary was conducted by the measurement model,and the PSF curve was drawn.On this basis,the defects'quantitative eval-uation model was presented according to the PSF curve for defects quantitative evaluation.The stainless steel sample containing artificial defects was analyzed by using the high-energy 6MeV industrial CT linear array detector system.The result shows that, compared with the traditional half-width defects measuring method,this method improves the accuracy of defects quantitative e-valuation.This method provides a new and effective tool for high performance of quantitative evaluation on the defects in metallic materials.
What problem does this paper attempt to address?