Experimental Study on Seal Line of Hanging-Downcomer

LI Yu-min,YU Xiao-mei,CHEN Ping
DOI: https://doi.org/10.3321/j.issn:1003-9015.2005.04.025
2005-01-01
Abstract:Hanging-downcomer tray has developed for 40 years, in which the hanging-downcomers are terminated in the disengagement space above the lower tray froth, so that vapor may rise up through the downcomer bottom-orifices which will cause the increase of the downcomer′s load. Therefore the hanging-downcomers are required to be sealed by liquid. The previous seal line proposed by Xu is too conservative, in which the criterion of almost not allowing the vapor to leak through the downcomer was set. A new criterion of vapor leakage is proposed here in which the frequency of vapor rising up through the downcomer is allowed to be once per second, according to which, the ratio of the leaking vapor rate through the downcomer to the total vapor rate will be less than 0.1%. Using the new criterion, the experiments determining the new seal lines were carried out in a 300mm×200mm plexiglass column with air water system. The muti-path conductomerter was used to measure the leakage fraction of the new seal line at various vapor and liquid rates. The experimental results show that the new seal line is more reasonable than the previous one and can more objectively reflect the hydraulic performance of hanging-downcomer or enlarge the tray stable-operating range. Finally, the new seal line is more applicable to the case of operation with medium and big rate ratio of liquid to vapor.
What problem does this paper attempt to address?