Studies on the Treatment of Chemical Industrial Wastewater by Pillar Bearing Bentonite

邵红,李颖惠,王冬梅,王恩德
DOI: https://doi.org/10.3969/j.issn.1671-0460.2003.02.008
2003-01-01
Abstract:The bentonite were modified by inorganic or organic pillar bearing process. The modified bentonite inserting were utilized in treating chemical industrial wastewater. The optimum applying conditions such as the amount of flocculants, the pH value were examined. The results of modified bentonite used in treating chemical industrial waste water showed that the highest COD removal rate of inorganic modified bentonite is 55.4 %. While the effect of simply using organic pillar bearing bentonite for treating L G waste water is not good. The highest COD removal rate is only 38.5 %.The joint use of AlCl_3 and Al_2(SO_4)_3 with organic pillar bearing bentonite can improve the COD removal rate from waste water significantly. And the effect of joint using Al_2(SO_4)_3 is better than AlCl_3,the COD removal rate can reach 75.6 %.The result is satisfactory.
What problem does this paper attempt to address?