Temperature Stress Analysis of an Overlength Basement Concrete Structure
WANG Qiang,YIN Runjie,LIU Guiling,LIU Ming,ZHANG Yibin,ZHANG Qianguo,RONG Xiufang
2009-01-01
Abstract:The purpose is to study the temperature stress of an overlength basement concrete structure in Shenyang,to point out the effective anti-cracking measures and to achieve the jointless design of the basement.Concrete expansion,hydration heat,shrinks and environment temperature changes were calculated through correlation theories.By analyzing basement structure under the overall difference in temperature by finite computing software ABAQUS,the characteristics of temperature stress of the base board,floor and exterior wall in setting and not setting the post-pouring strengthening band were studied.The results show that the temperature stress of the basement of construction of stage 1 without the post-pouring strengthening band was larger,the stress of the basement with the post-pouring strengthening band decreased obviously;the stress of the corner,the cave-side and the local narrower parts between the holes was the largest.The conclusion shows that the expansion joint may not be set in an overlength basement by setting the post-pouring strengthening band and temperature reinforced reasonably,adopting the shrinkage-compensating concrete along with doing a good job in temperature difference,materials,production technology of concrete and construction.