Numerical Simulation on Screening by Air Curtain in Long Narrow Channels

Ji-wei ZHOU,Ran Huo,Long-hua HU
DOI: https://doi.org/10.3969/j.issn.1009-6094.2005.04.034
2005-01-01
Abstract:The present paper aims to introduce the authors' numerical simulations on finding possibility and efficiency to hold smoke back in the long-narrow channels by using an air screen. Actually, there exist three most important factors that influence the smoke control efficiency: i.e. the velocity of the wind, its onward obliquity of the outlet, and the relative position of the discharge vent at the floor level. In order to make clear the influence of the three factors, numerical simulations are done to simulate the smoke control efficiency by air curtain. The results of simulations have shown that the smoke control efficiency tends to be enhanced when the onward obliquity or the velocity of the outlet wind is increased. Besides, properly adjusted straight-forward movement of the discharge vent can also improve the smoke control ability of the air curtain. But when the fire size is relatively too large or the velocity of outlet wind was too small, the air curtain will fail to hold smoke back effectively. Finally, it can be drawn from the numerical simulations that the air curtain could hold smoke back effectively in the long-narrow channels when these three factors can be taken into consideration comprehensively.
What problem does this paper attempt to address?