Research on emission control of vehicle fuel-fired air heater

Fu-lin SHEN,Yong ZHANG,Jin-gang GUO
DOI: https://doi.org/10.3321/j.issn:1001-7372.2005.04.024
2005-01-01
Abstract:For the serious exhaust pollution of a fuel-fired air heater during the start and stop periods,a technique was proposed to reduce its emission,in which a ceramic ignition system was adopted and the oil-supplying system was improved.A comparison showed that the densities of CO and HC kept almost no decline while the smoke value of OPAC decreased and the exhaust time at the start became shorter after a ceramic ignition system was introduced;the amount of HC decreased to 30% of the initial value,CO to 3% and OPAC to 28%,and at the same time all the types of the exhaust time at the stop period were shortened, by improving the oil-supplying system.The results of the experiments demonstrate this technique can effectively reduce the exhaust pollution of a fuel-fired air heater during the start and stop periods.
What problem does this paper attempt to address?