Experimental Study on Peeling Performance of T-type Brazing Joints

Peng-Yang Duan,Dong-Xing Wang,Guo-Yan Zhou,Shan-Tung Tu
DOI: https://doi.org/10.1016/j.ijpvp.2019.03.010
IF: 2.56
2019-01-01
International Journal of Pressure Vessels and Piping
Abstract:As the key component of the high temperature gas cooled reactor (HTGR), the performance of the plate fin heat exchanger determines the working efficiency and life of the HTGR. Although the plate-fin structure has lots of advantages such as high efficiency, compact structure, low manufacturing cost, its application will be affected by the vacuum brazing technology and harsh conditions, like high temperature and high pressure. In the practical application of plate-fin heat exchanger, the process of "splitting" between the fin and the diaphragm is very similar to that of the adhesive joint and the delamination of the composite. In the present study, a T-type specimen was designed for the the peel testing of brazed joints. Five kinds of specimens were designed based on the difference between the weld gap and the thickness of the sample base material. The tests were carried out under 450°C and 650°C at five kinds of loading rates, respectively. The peel force-displacement curves of standard samples were obtained . The maximum peel strength and average peel strength were calculated. In addition, the influence of base metal thickness, brazing gap, loading rate and test temperature on the maximum peel strength were analyzed by controlling variable method. Keywords: brazing joint; T-type peel test
What problem does this paper attempt to address?