Macro-instability regulated by double rigid-flexible combination impeller

ZHU Jun,LIU Zuohua,ZHENG Xiongpan,CHEN Chao,WANG Yundong
DOI: https://doi.org/10.11949/j.issn.0438-1157.20141058
2015-01-01
Abstract:Fluid macro-instability is a large scale low frequency transient quasi-periodic phenomenon existing in stirred vessel, and affects fluid energy and mass transfer behavior. To reveal the nature of unsteady flow in a stirred vessel with double rigid-flexible impeller, tap water was used as working fluid, and wavelet analysis and flow field visualization were adopted to analyze the influence of double rigid-flexible impeller on the frequency of macro-instability. The difference between double rigid and double rigid-flexible impellers was analyzed in terms of mixing performance. The frequency of macro-instability increased linearly with agitation speed. At agitation speed 180 r·min?1, macro-instability frequency values of rigid-flexible impeller were 0.5096 Hz and 0.3459 Hz with off-bottom clearance 0.33T and 0.5T, respectively. Compared with double rigid impeller system, mixing time was shortened by about 22.5% and 35%, respectively. But macro-instability with off-bottom clearance 0.25T disappeared and bands phenomenon appeared. Shortening the off-bottom clearance could reduce the regular area. Double rigid-flexible combination impeller regulated fluid macro-instability and strengthened energy transfer behavior, so as to shorten mixing time and improve mixing efficiency of the fluid.
What problem does this paper attempt to address?