Scaling analysis and design for PCS air flow path natural circulation

Zhuo Liu,Hua-Jian Chang,Xiang Yang,Yan-Ning Yang
DOI: https://doi.org/10.7538/yzk.2016.50.02.0254
2016-01-01
Abstract:The scale‐down separate and integral effect test facilities are of vital signifi‐cance not only for the research and development of large‐scale advanced pressurized w ater reactor nuclear pow er plants ,but also for validation and verification of the related analysis codes . The passive containment cooling system (PCS ) air flow path system plays an important role in containment passive cooling .Based on the natural circulation model ,the scaling and design methods for both the separate and integral effect test facil‐ities were proposed .Under given heat flux from the inner side of the shell ,simulation of an ideal scaled facility (ISF) design of a 2/5 length scaled separate effect test facility for CAP1400 PCS was preliminarily performed by the PCCSAP‐3D code .The simulation results show that the design method and the modeling of natural circulation on a reduced height test facility are feasible .
What problem does this paper attempt to address?