Abstract:Integral test plays a key role in assessing the performance of the passive core cooling system of the advanced passive nuclear reactor design.The scaling analysis of two-phase natural circulation behavior in primary loop provides the theoretical basis for determining the characteristics scale size of the integral test facility.Based on two-phase drift flow model,a steady-state solution of the flow condition was obtained by integrating the governing equations of the loop two-phase natural circulation.The governing equations were then non-dimensionalized straightway using the initial or boundary condition.Finally,the similarity criteria that should be preserved between the prototype plant and the integral facility was given.