Assessment of Scaling Distortion in Condensation Film Heat Transfer

LIU Zhuo,CHANG Hua-jian
DOI: https://doi.org/10.7538/yzk.2014.48.11.1969
2014-01-01
Abstract:The scale‐down separate and integral test facilities are of vital significance for the research and development of both large‐scale advanced pressurized water reactor nuclear power plants and the related analytical codes .However ,the distortions of some phenomena induced by the reduced size have directly affected both the design of the facility and the understanding of the test results .Through the equivalent heat transfer coefficient ,the distortion of condensation film heat transfer on the inner side of PCS w as assessed .With the use of H2TS scaling method , the effect of this distortion on the modeling of containment pressure change response w as analyzed .T he results show that the scale‐dow n of a test facility has a conservative influence on the condensation film heat transfer .
What problem does this paper attempt to address?