Decoupled Thermal-Hydraulic Analysis of an Air-Cooled Separated Heat Pipe for Spent Fuel Pools under Natural Convection

Huilin Xue,Jianjie Chen,Weihao Ji,Wenjin Li,Hanzhong Tao,Wei Li
DOI: https://doi.org/10.2139/ssrn.4211308
2022-01-01
SSRN Electronic Journal
Abstract:This paper modeled the spent fuel pool (SFP) of the CAP1400 pressure water reactor in Weihai and used CFD to explore the heat dissipation capacity of the separated heat pipe SFP passive cooling system (PCS) under different air temperatures and wind speeds. To study the effects of the external environment on the temperature of the SFP under natural convection conditions, the coupling heat transfer processes in the PCS were decoupled through the principle of heat balance. The research finds that the model verification error is within 10%. And when the air temperature is 10°C, or the wind speed is about 8m/s, the separated heat pipe can achieve the best performance. Based on the thermal resistance network model, the fitting formulas of the equivalent thermal conductivity of the heat pipe are summarized with the changes in air temperature and wind speed.
What problem does this paper attempt to address?