Development of 1 . 5 W 4 K Two-Stage Pulse Tube Cryocoolers with a Remote Valve Unit

A. Tsuchiya,X. Lin,H. Takayama,M. Saito,M. Xu
2014-01-01
Abstract:Sumitomo Heavy Industries, Ltd. (SHI) has been continuously improving the efficiency and reducing the vibration of a 4K pulse tube cryocooler. Recently, a 1.5W 4K pulse tube cryocooler (PTC) with a remote valve unit has been developed. The valve unit of the cryocooler is split from the cold head by a flexible gas line and two stainless pipes. When the valve unit is split with 1 m lines, the cooling capacity is reduced because of increased pressure drop and dead volume. The typical cooling capacity of the prototype unit is 35 W at 43.5 K at the first stage and 1.35 W at 4.13 K at the second stage when the compressor is operated at 50 Hz. The cooling performance load map and the performance with respect to the opening of the second stage orifice will be reported in this paper. INTRODUCTION SHI has been developing 4K pulse tube cryocoolers for various applications. 1W 4K pulse tube cryocoolers, RP-082B2, and same series with a remote valve unit, RP-082B2S are currently released. In the RP-082B2S unit, vibration has been greatly reduced by splitting the valve unit from the cold head at the expense of a cooling capacity degradation of about 0.1 W at 4.2 K . Lately, applications for pulse tube cryocoolers, e.g. dilution cryocoolers, need more cooling capacity. Owing to the recent unstable supplement of liquid helium, the demand for high cooling capacity 4K cryocoolers has been increasing. Recently, SHI developed a more efficient pulse tube cryocooler based upon an existing model, RP-082B2S. The pulse tube and regenerator cylinder size are redesigned to increase the ideal cooling capacity. In an SHI 1W 4K pulse tube cryocooler, DC flow rate, which can significantly affect the cooling capacity, is not fully optimized. In order to optimize the DC flow rate at the second stage, an additional orifice is installed between the warm end of the second stage pulse tube and the low pressure side of the compressor. By optimizing the DC flow rate, a significant cooling capacity improvement at the second stage has been achieved. As a result of the above-mentioned redesign, a significant cooling capacity improvement has been achieved. A typical cooling capacity of a prototype unit with a remote valve unit is 35 W at 43.5 K at the first stage and 1.35 W at 4.13 K at the second stage when the compressor is operated at 195 211 Cryocoolers 18, edited by S.D. Miller and R.G. Ross, Jr. ©¶International Cryocooler Conference, Inc., Boulder, CO, 2014
What problem does this paper attempt to address?