Prediction and Analysis of the Axial Force of Pump-Turbine During Load-Rejection Process

Xiangyang Li,Zhongyu Mao,Wenhua Lin,Huili Bi,Ran Tao,Zhengwei Wang
DOI: https://doi.org/10.1088/1755-1315/440/5/052081
2020-01-01
IOP Conference Series Earth and Environmental Science
Abstract:Load-rejection is an important process of pump-turbine unit. In this process, hydraulic characteristics would change greatly. The axial force of runner and of the entire shaft system will be impacted. This study focuses on a prototype pump-turbine unit. The axial force of this unit during load-rejection is predicted and analyzed. The hydraulic transient analysis can give a more accurate boundary condition of pump-turbine. The computational fluid dynamics simulation considering the full leakage in runner crown and shroud can have a comprehensive prediction of the axial force. Results show that the rotation speed, head and flow rate change during load-rejection process. The axial force is also influenced and changes. The law of axial force variation has a strong relationship with the flow rate variation law. The internal flow analysis found that the pressure difference between crown leakage and internal-runner near outlet is the key factor in inducing axial force. This pressure difference is strongly influenced by runner internal flow regime. During load-rejection process, flow rate strongly varies and causes the huge change of internal flow regime. This is the main reason that runner axial force changes positive and negative alternatively.
What problem does this paper attempt to address?