Mechanism and suppression method for feedback-caused close-loop position fluctuation of electrostatically suspended accelerometer

LIU Shuang,LIU Yun-feng,DONG Jing-xin
DOI: https://doi.org/10.13695/j.cnki.12-1222/o3.2014.05.024
2014-01-01
Abstract:The nonlinearity of electrostatically suspended accelerometer (ESA) is related to the closed-loop position of proof mass (Pm), which can be adjusted by changing the output of detection circuit (Udc). It is found that Udc can be changed by feedback voltage (Vb) during the adjustment, thus causing the fluctuation of Pm. In order to solve this problem, the relationship between Pm and Udc is studied, and the transform function of detection circuit is deduced. The contrast test is carried out with C0G, Y5P, X7R and SL capacitances under different Vb and frequencies. Theoretical and experimental results show that the reason for the fluctuation of Udc caused by Vb is the variation of the isolation capacitance caused by Vb. Using the C0G capacitance, which is immune to temperature and high voltage and frequency, not only could overcome the fluctuation of Pm during adjustment, but also improve the stability of the detector circuit.