X-ray Measurement System Based on Attenuation Transmission Method for Tokamak

Weiwei Fan,Zejie Yin
DOI: https://doi.org/10.1109/ICICTA49267.2019.00159
2019-01-01
Abstract:A novel X-ray energy spectrum measurement system for tokamak is developed. The system is based on attenuation transmission method by the means of aluminum bars attenuating incident X-rays. The detection module consists of LYSO, attenuated aluminum bars of eight different lengths and collimating apertures and they are all integrated in a shield block composed of lead. The particle model has been carefully established by Geant4 and the whole transmission process is simulated. The preamplifier and data acquisition (DAQ) module for detector output signals processing provide great convenience for system measurement. Real-time, parallel and pipelined algorithms are implemented in the high-performance field-programmable gate array (FPGA). The system has been test in laboratory and excellent results are obtained. Compared with the simulated result, reconstructed energy spectrum is in good agreement with it, proving the reliability and practicability of the system.
What problem does this paper attempt to address?