Optical Design of the Lyman Alpha Based Beam Emission Spectroscopy(lab)diagnostic on the HL-2A Tokamak
Yixuan Zhou,Huajie Wang,Yi Yu,Yihang Chen,Rui Ke,Min Xu,Chijie Xiao,Zhanhui Wang,Jiquan Li,Xuru Duan,Minyou Ye
DOI: https://doi.org/10.1088/2058-6272/ac0327
2021-01-01
Abstract:In this article, we present the optical design of a novel diagnostic on the HL-2 A tokamak, i.e. the20-channel edge Lyman-alpha beam emission spectroscopy, which is a promising solution for edge density turbulence research on tokamaks, as it offers the possibility of density fluctuation measurement with a 3.3 mm spatial resolution while maintains a high temporal resolution of1 μs. The optical path, including the reflective collection optics, the high-dispersion spectrometer, and the linear detector array, is carefully optimized to obtain a good image quality and a high throughput. The maximum root mean square radius of the collection optics is 64 μm.The detected photon flux is estimated to be about 10 11 photons/s/channel.
What problem does this paper attempt to address?