Microwave Diagnostics System in the HL-2A Tokamak

Ying-liang LI,Xuan-tong DING,Ze-tian LIU,Zhong-bing SHI,Wei-wen XIAO
DOI: https://doi.org/10.3969/j.issn.1005-6122.2006.01.013
2006-01-01
Abstract:In this paper,some of the microwave techniques used in plasma diagnostic systems on nuclear fusion device HL-2A tokamak are introduced.The basic principle,the circuits of every microwave diagnostic system and the measurement results in discharge are systematically presented.The electron temperature and its fluctuations of the main plasma are measured by electron cyclotron emission(ECE).The temporal and spatial resolution are up to 4 ms(swept frequency) or 1μs(single frequency)and 3cm respectively.The electron temperature range of the system is from 10ev to 10kev.With the microwave reflectometry,we can study the density profile,rotation and fluctuation of the plasma.The temporal resolution and the spatial resolution are 1ms and 1cm respectively.The average density of plasma in the diverter of the HL-2A tokamak is measured by microwave interferometer with 0.1ms temporal resolution.
What problem does this paper attempt to address?