A Typical Super-Heater Tube Leakage and High Temperature Corrosion Mechanism Investigation in a 260 T/h Circulated Fluidized Boiler

Xiaohe Xiong,Zhaomin Lv,Houzhang Tan,Bo Wei
DOI: https://doi.org/10.1016/j.engfailanal.2019.104255
IF: 4
2019-01-01
Engineering Failure Analysis
Abstract:Aiming to explore the high temperature corrosion mechanism in a 260 t/h circulated fluidized boiler, a section of bursting super-heater tube was cut down and the scanning electron microscope relevant characterization analysis was conducted. Results show that the major compositions in the corrosion products are iron oxide such as Fe2O3, Fe3O4 and FeCr2O4 rather than sulfide, occupying a rough 70% mass ratio. The corrosion type is not typical H2S corrosion but salt corrosion. The sodium sulfate and sodium chloride are both found covered on the superheater tube surface, but the sodium sulfate is the major corrosion culprit. Line scan results show that the layered structure of two oxidation layers are obviously observed. The chromium is enriched in the inner layer with a depth of 572 mu m while the iron is full of the whole oxidation layer with a 1017 mu m depth. The chromium oxide layer is compact and can diminish the corrosion rate. The iron oxide layer is loose and porous and can supply the transfer path to the oxygen medium. To alleviate the high temperature corrosion, thermal spay coatings, aluminized steel tube, coal quality control etc. these measures are suggested and put forward.
What problem does this paper attempt to address?