Numerical Research on the Influence of Declination Angle on Carrying Capacity of Tertiary Air, Ignition, and Combustion Characteristics of Pulverized Coal of 300 MW Down-Fired Utility Boiler with Multi-Injection and Multi-Staging Combustion Technology

Lingyan Zeng,He Du,Wenjie Liu,Zhenhua Yuan,Shuxuan Liu,Cheng Xie,Xiuchao Yang,Xiaoguang Li,Zhichao Chen,Zhengqi Li
DOI: https://doi.org/10.1061/(asce)ey.1943-7897.0000627
2019-01-01
Journal of Energy Engineering
Abstract:A new burner arrangement mode is proposed for a 300-MW down-fired boiler burning bituminous coal (V-daf=23.59%). Under the new burner arrangement, 21.99% of the total air volume is arranged as tertiary air, which is helpful to promote the burnout of pulverized coal and reduce NOx emissions. Numerical simulations were carried out to study the influence of tertiary air declination angle on boiler performance. The slope of the dimensionless velocity attenuation curve-fitting line was introduced to quantitatively analyze the carrying capacity of tertiary air. Results show that as declination angle increased, ignition distance of fuel-rich coal/air flow decreased from 1.35 to 1.03 m. The slope of the dimensionless velocity decay curve-fitting line increased from -2.23 to -1.28. The dimensionless penetrating depth of gas flow increased from 1.1 to 1.45. Carbon content in fly ash, NOx emissions, and oxygen concentrations at the furnace outlet all basically had a trend of decreasing first and then increasing. At a declination angle of 35 degrees, carbon content in fly ash and NOx emissions were the lowest, 4.19% and 675.92mg/m(3), respectively. Therefore, the optimum tertiary air declination angle of boiler with new burner arrangement should be 35 degrees. (C) 2019 American Society of Civil Engineers.
What problem does this paper attempt to address?