Precision Two-Stage Voltage Transformer for a Wide Voltage Range of 5–40 kV

Hao Liu,Enrico Mohns,Johann Meisner,Chunyang Jiang,Feng Zhou,Xiaodong Yin,Lixue Chen
DOI: https://doi.org/10.1109/tim.2023.3296126
IF: 5.6
2023-08-09
IEEE Transactions on Instrumentation and Measurement
Abstract:A two-stage voltage transformer (VT) with several rated transformer ratios and with a rated maximum voltage of 40 kV and a rated minimum voltage of 5 kV has been designed. To guarantee high accuracy over the full medium-voltage range, the primary winding has been split into four primary windings, which can be configured in three different series and parallel connections. With five windings of the secondary, 15 different voltage ratios can be accomplished. This connection scheme, which is already used in older commercial standard VTs of the error class 0.02, achieves a very low effective output resistance, which in turn results in very small additional errors of less than due to the loading by the input of the transformer bridge. According to the measuring results, for all the 15 different ratios, the error is less than /V for ratio error and rad for phase displacement.
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?