Clearance Measurement Equipment for Gas Lubricated Dynamic Pressure Bearing of Gyro Motor

Tong-qun Ren,Zhi-rou Liu,Xiang-dong Xu,Yu Liu,Xiao-dong Wang
DOI: https://doi.org/10.1007/s12541-019-00235-5
IF: 2.0411
2019-01-01
International Journal of Precision Engineering and Manufacturing
Abstract:The clearance of gas lubricated dynamic pressure bearing of gyro motor refers specifically to small internal air gap between the rotor and stator. The clearance size is an important indicator of running performance of a motor. In this work, a dedicated clearance measurement equipment is developed. The clearance is converted to external micro displacement and measured by dual inductive probes with relative measurement principle. For this purpose, three main functional modules are designed together with corresponding electronic and pneumatic control systems. The clamp fixation module helps to support the measured bearing flexibly at the shaft end, which is conducive to protect the bearing and ensure the smoothness of force application. The force application module consists of a 3-D precision motion platform and a triaxial force sensor. It converts internal air gap to external micro displacement in cooperation with the clamp fixation module. The displacement measurement module is a 2-D precision motion platform carrying dual inductive probes. Based on theoretical analysis and practical experiments, the measurement accuracy is superior to 0.3 μm. Moreover, it realizes controllable and continuous force application, which is suitable for batch measurement.
What problem does this paper attempt to address?