Improving the Noise Immunity of the Vortex Flowmeter Measurement Signal

M. Prakhova,I. N. Mymrin,A. N. Krasnov
DOI: https://doi.org/10.1109/ICIEAM51226.2021.9446338
2021-05-17
Abstract:Vortex flowmeters, in particular, those with piezoelectric sensors have recently been expanding their flow measurement market presence due to their versatility to controlled process media and operating conditions. Herewith, the market offers both premium and fairly budgetary flowmeter models, which differ in the degree of the measurement signal immunity to various noises, mainly external vibration. The paper proposes a relatively simple algorithm for eliminating the vibration noise impact when the frequency spectra of this noise and the measurement signal do not overlap. It comprises a software processing of a certain array of experimental data based on the fast Fourier transform in the MATLAB application software package. Data are taken directly at the flowmeter site. The algorithm proposed allows considering the dynamic vibration component that depends on the flow rate in vortex flowmeters without special protection, which improves the overall measurement accuracy.
Engineering
What problem does this paper attempt to address?