Impact Analysis of Vortex Flowmeter Measured with Duct-Wall Differential Pressure Method

SUN Zhi-qiang,ZHANG Hong-jian,HUANG Yong-mei,HAN Xue-fei
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.12.018
2006-01-01
Abstract:In order to improve the anti-disturbance ability and stability of vortex flowmeter without influencing its accuracy,a new method by using duct-wall differential pressure was proposed to measure vortex frequency.Systematic experiments were performed in the cases of water and air respectively.Based on the theory of vortex dynamics and fluidic impedance,the impacts of pressure-sampling position and joining pipe's frequency response on measured performances of the method were investigated.The experimental results show that pressure-sampling position has little effect on the Strouhal number and meter coefficient in a certain vicinity downstream from the bluff body.The nearer the pressure-sampling position is to the bluff body,the smaller is the minimum measurable flowrate.The joining pipe length should be made as short as possible and its natural frequency must be far from the vortex frequency.The method is simple and reliable,has strong adaptability,and reduces the minimum measurable flow limit.
What problem does this paper attempt to address?