Study on Improved Measureement Ciricuit for Vortex Flow Frequency

YAN Zhan-ke,ZHOU Hong-liang,ZHANG Hong-jian,SUN Zhi-qiang
DOI: https://doi.org/10.3969/j.issn.1002-1841.2006.04.014
2006-01-01
Abstract:The vortex frequency measurement is one of the key techniques in vortex flowmeter.As the vortex frequency is proportional to flowrate,it varies in a wide range.Often affected by various disturbances in industrial plant,it is hard to increase the measurement accuracy of vortex frequency.Bassed on traditional measurement circuits of vortex flowmeter,by analysing the features of the vortex frequency,this paper proposed an improved circuit by adopting adaptive filtering and adaptive expansion of period.The results from simulation and experiments show that the method can weaken disturbances and increase the measurement accuracy effectively.
What problem does this paper attempt to address?