Leakage Current Analysis and Arc Identification in AC Incline Plane Test

XU Sen,WU Chao,LIANG Xidong,LIU Yingyan,LIU Bo,HUANG Ruiping
DOI: https://doi.org/10.13335/j.1000-3673.pst.2017.2578
2018-01-01
Abstract:Composite insulator shed materials must have outstanding performance resisting tracking and erosion to insure reliability in long-term service. Inclined plane test (IPT) is a common testing method for materials' resistance of tracking and erosion, and leakage current analysis is an important tool for investigating IPT severity. In this paper, a novel arc identification algorithm was designed for AC IPT, and the leakage currents of high temperature vulcanized silicone rubber (HTV) samples in 4.5 kV standard IPT were analyzed. It turned out that the arc parameter distributions of HTV samples possess long-tail effects. Due to the long-tail effects, arc parameters would not strictly comply with normal or log-normal distribution. According to moving average curves of arcing time, erosion processes of HTV samples were divided into slow-and fast-erosion stages. Arc parameters almost maintained stable in slow-erosion stage, but steeply changed when the samples entered into fast-erosion stage.
What problem does this paper attempt to address?