Abstract:In order to study the circumferential distribution of leakage current for the specimen with larger diameter and its influence on the ageing of the specimen in the tracking wheel test, a whole test with a duration of 30 000 cycles was conducted on two large-diameter specimens under the recommended test method proposed in the first part of the two-part article. The leakage current was divided into 8 channels circumferentially. The results show that leakage current of the lower part in the drip position is generally larger than that of the upper part and comes into the third stage earlier, which means that the hydrophobicity in this part loses faster. The cumulative charge for each channel has the same law. The minimum value is about 0.61 and 0.62 time of the maximum value for the two specimens, respectively. There is no severe tracking or erosion for the two specimens. It is concluded the circumferential distribution of leakage current and arcing will not influence the tracking wheel test on specimens with relatively large diameters.