Split-Capacitor Passive Damping Control for LCL Grid-Connected Inverter

WANG Haisong,WANG Han,ZHANG Jianwen,CAI Xu
DOI: https://doi.org/10.13335/j.1000-3673.pst.2014.04.012
2014-01-01
Abstract:ABSTRACT:The passive damping scheme adopting capacitor branch in series with resistor can solve the current resonance in LCL filter based grid-connected inverter well, however there is a defect in such a scheme that the power loss of damping resistor is high. In allusion to it, a split-capacitor passive damping scheme is proposed. In the proposed scheme the capacitor branch of LCL filter is equally divided into two parts and the damping resistance is only connected to one of the two parts. Using the proposed scheme, the damping effect of LCL filter under the amplitude of natural resonance is theoretically analyzed, and the power loss of the proposed scheme adopting different damping resistance is compared with that of traditional scheme. Comparison results show that selecting appropriate damping resistance almost the same damping effect can be achieved as by traditional unsplit capacitor damping scheme and the power loss of damping resistor can be reduced. The correctness of theoretical analysis is verified by simulation results.
What problem does this paper attempt to address?