Dual Current Feedback Active Damping for Improving Transient Performance of LCL-filter-based Grid-connected Inverter

Minghan Dong,Zhihong Bai,Hao Ma
DOI: https://doi.org/10.1109/isie.2019.8781550
2019-01-01
Abstract:This paper aims at improving transient performance of LCL-filter-based grid-connected inverters with active damping. Transient performance of inverters controlled by capacitor current feedback active damping (C 2 FAD) is analyzed, revealing that grid-currents of the inverters may have overshoot and long settling time when loads fluctuate. To improve transient response better than C 2 FAD do, a dual current feedback active damping (DCFAD) is proposed. The proposed DCFAD could realize virtual resistor connected in parallel with capacitor and virtual resistor connected in series with grid-side inductor, consequently, adding a control parameter to the algorithm to configure the poles effectively without adding sensors. Experimental results based on a single-phase grid-connected inverter prototype with LCL filter are presented to demonstrate that DCFAD could eliminate overshoot and reduce settling time, when comparing with C 2 FAD.
What problem does this paper attempt to address?