Research on Splitting Capacitor and Repetitive Control for Grid-connected Inverter With LCL Filter

CHEN Rui-rui,CHEN Hui-ming,WANG Zheng-shi
DOI: https://doi.org/10.3969/j.issn.1000-100X.2013.07.013
2013-01-01
Abstract:Grid-connected inverter has better high-frequency current harmonics attenuation performance through an LCL filter.However,the LCL filter structure is a third-order no damping system,having resonance peak and hard to design an appropriate controller.Hence,a novel control strategy is proposed that combined the splitting capacitor current feed-back of LCL filter and repetitive control.By this way,the system is simplified from third-order to first-order and the performance is improved.The advantage of repetitive control,which means restraining periodic disturbance effectively is remained,meanwhile,the design of repetitive control compensator is simplified.System analysis and design are presented.Experiment on a 2 kW prototype is done to show the validity of the proposed control strategy.
What problem does this paper attempt to address?